01

Steps

PUMP Inspection

before using

First, check whether the pump is in good condition and whether there are any missing accessories.

Next, firmly install the pump and motor. The two pulleys are in the same line, and the belt is moderately tight.

After installation, turn the pulley by hand to check whether it can rotate smoothly. If it is too tight or cannot rotate, generally is caused by the distance between the pump and the motor.

The pump must be filled with oil (No. 30 oil is recommended) and added to the 2/3 position of the oil detector. Too little oil might create noise, too much oil might create heat. The sticker on the fuel cap must be removed to keep airflow in the tank.

Before starting the motor, first release the pressure and turn on the water outlet switch so that the water can be absorbed faster. The recommended speed of the pump is 500~900r/Min. These are some steps for you to check before you start using the power sprayer!


maintenance

of the pump

Regarding the intensity of use, observe whether there is backwater. If not, it may be due to insufficient flow.

After each use, the residual liquid in the pump should be cleaned and discharged.

Regarding the oil, change the oil for the first 10–30 hours of use because the oil will be dirty after the first use. Then change it every 70 hours and pay attention to keeping the oil above the 1/2 position of the oil detector.

02

care

03

questions

Troubleshooting

find and solve

Q: There is no water supply.

A: There is air in the water inlet pipe. Check if the hose is tightened, the sealing ring has not fallen off, or the valve group has not been stuck with objects.

Q: There is insufficient pressure.

A: The pressure that generated after a long time of usage is insufficient. Replace the V tightening ring and valve collars, and check the tightening screws of the pump.

Q: There is temperature increase from the pump.

A: The connecting rod is stuck, cannot work smoothly and damaged the crankshaft. Replace both connecting rod and crankshaft.
 For more other questions, contact our professional staffs!


Tinkerbell black clear

ZHEJIANG TINKER BELL TRADING CO., LTD

The guarantee manufacturing agricultural machinery spare parts and equipment since 1980.

Spare Parts

Menu

[wpforms id=”407″ title=”false” description=”false”]

Copyright @ ZHEJIANG TINKER BELL TRADING CO., LTD